Q: My wife started complaining about a lack of hot water, so I ventured out into the garage to check out the water heater. I took the door off and peeked inside and discovered there was no flame. Following the instructions on the tank, I relit the pilot but as soon as I let go of the button, the pilot light went out. I originally thought a breeze may have blown it out, but now I don’t know what to do.

Q: My wife started complaining about a lack of hot water, so I ventured out into the garage to check out the water heater. I took the door off and peeked inside and discovered there was no flame. Following the instructions on the tank, I relit the pilot but as soon as I let go of the button, the pilot light went out. I originally thought a breeze may have blown it out, but now I don’t know what to do.

A: It sounds like a problem with your thermocouple. It is a $15 part that is a safety device at the base of your water heater.

The thermocouple acts as a switch. On one end is a part that looks like a rectal thermometer (this part sits in the flame of the pilot). On the other end is a fitting that screws into the gas valve. Connecting the two ends is a wire.

The part works like this: As the one end is heated by the flame, a small electrical charge is generated that tells the gas valve to remain open. When the pilot light goes out, the charge stops and the gas valve closes. This prevents gas from continuing to fill up the base of your water heater.

So this little $15 part does a pretty important job. If the thermocouple is bad, no gas will flow and the pilot will not light.

To change the thermocouple, you will need to disconnect several parts to access it. Before you do anything, though, turn off the gas to the unit. Turn the knob on top of the gas valve to the “off” position and turn off the gas supply valve where the gas flex line connects to it.

There are three lines coming out of the bottom of the water heater’s gas valve. The burner’s gas line, which is about as thick around as your pinky finger; the pilot light’s gas line, which is about ⅛-inch in diameter; and the thermocouple, which looks like a copper wire. It is the skinniest line there.

Gently unscrew the three lines from the gas valve and maneuver the burner assembly and thermocouple out of the chamber. There is a small door that you will need to remove to gain access.

The burner may have a tab at the bottom that slips into a slot at the bottom of the water heater. If so, just lift and push it out of the slot.

Some thermocouples just push into the bracket that holds the pilot in place. Others are secured by a threaded fitting.

Unscrew the thermocouple fitting at the bracket (or if you’re lucky just pull it out). Your new thermocouple will come with several universal fittings for different sizes and methods of connecting it to the bracket.

With the thermocouple in place, maneuver the burner assembly back into place and connect the gas lines and new thermocouple to the gas valve. Turn the gas back on and follow the directions on the tank to relight the pilot.

Mike Klimek is a licensed contractor and owner of Las Vegas Handyman. Questions may be sent by email to handymanoflasvegas@msn.com. Or, mail to 4710 W. Dewey Drive, No. 100, Las Vegas, NV 89118. His web address is www.handymanoflasvegas.com.

A disease called fire blight might pop up in some pear and apple trees beginning around May. It can be common several weeks after spring rains, particularly if trees were flowering. It can lead to tree death if not controlled when it’s first seen.

Delay pruning grapes as long as possible in the spring to reduce disease possibilities and avoid any late spring frost damage after pruning. Immediately after pruning grapes, consider applying a fungicide to the vines if there were problems with grape bunch diseases last year.

Turning a small space into a rental unit takes some tricks of the trade to make the space appear larger. Creative storage is paramount.

So often the driving force behind such renovations is the pool surface, a cement-based coating of about three-eighths of an inch over the gunite structure. Because of Las Vegas’s hard water, the longevity of a gunite pool surface is 10-12 years.

If your outdoor box cover has the doors that must stay open to access electricity, there is an easy fix: You can buy a weatherproof box cover that is made for use during rain or when your sprinklers hit it.

My experience with Mexican petunia is that it grows like a weed, and I consider it the broadleaf version of Bermuda grass, aka devil grass. If it’s contained in an area and prevented from spreading into the landscape, I think it will be OK.

Although the official start of spring is March 19, warmer weather has arrived in Las Vegas and the cleaning season is definitely here.

An infrequent desert rain is not a problem. But when irrigation water is applied over and over to a soil that is normally dry, these soils shift, collapse and chemically change. In urban landscapes, this can be potentially destructive.

When preparing to prune plants, follow these three rules: adjusting loppers or hand shears so they don’t rip plants instead of cutting them, making sure the blade is sharp for the same reason and sanitizing the blades.

There are lots of different types of faucets, and they use different methods to control the flow and temperature of water. Over time the parts wear out and you get a drip. You need to replace the washers and springs and, possibly, the ball if it shows signs of wear.

Barrel Nipple Bspt Male Thread

Ball Valve, Check Valve, Flange Valve, 150lbs Threaded Fittings - Co-win,https://www.cowinvalves.com/